Service
Purchase and product...
Service promise
    
Purchase and product maintenance   Home<-Service 

Clean and maintenance for shower room:
1. Daily cleanness: Using the soft cloth with neutral detergent to clean it. If it is not easy to clean the dirt, toothpaste or low-density vinegar can be used (need to refer to the instruction), and then wash it with clean water.
2. Clearing of furring: cleaning the shower room with weak acid detergent, such as Lemon juice or vinegar heated to a certain temperature (a little hot). After cleaning, please wash it with clean water.
3. If there is scratch on the surface of the room body, please use the 1500# waterstone abrasive paper dip with water to make the surface smooth, and then cover little toothpaste to polish it with soft cloth.
4. Cleanness for electroplated parts: Using motarium to clean the surface of the electroplated parts, but the rough cloth and the organic solvent are forbidden to use. Besides, the glass cement gas with acid will corrode the electroplated parts, so please avoid the touch between the gas and parts.
5. Please do not use rough tools and clean agent with chemical solvent or pellet to clean the surface of the room, and please don't use objects with edges and corners, and cutting tools to knock or scratch the surface of the shower room.
6. Making sure the cess-pipe unblocked, please clean it often.
7. Detergent with corrosivity is not allowed to use, and the corrosive water cannot be poured into the bathtub. Objects whose temperatures are more than 100 degrees should avoid touching the surface of the shower room, or will damage the shower room.
8. During the transportation, please handle the product with care, avoid standing much weight, colliding or strong shaking. If don't use it for a long time, please keep the surrounding dry, ventilating and without corrosive gases.
Troubles
Reasons
Methods of clearing
Lights can’t work
(Roof lamp or back lights)
Electrical interface is loose
Lights have problems.
Reconnect the interface.
Change the lights.
Ventilation fan can’t wheel
Electrical interface is loose
Fan has problems.
Reconnect the interface.
Change the fan
Loudspeaker has no sound
Volume on computer panel is too low
Interface of the loudspeaker has loosen or broken.
Computer control box has broken.
Adjust the volume.
Reconnect or change the
Loudspeaker.
Change the computer control box.
The radio channel is unclear
The antenna is not pulled or its position is not right.
The frequency adjustment is not good.
Signal in user’s area is weak.
Pulled the antenna and fix it.
Readjust the radio frequency
Attributed to the signal of user’s area.
No electricity
The leakage protection switch is off or the jack has no electricity.
The electric control box is not connecting well with transformer.
There is leakage on electric source or wire.
Check the leakage protection switch and the jack.
Reconnect the wire.
Test the electric source, circuit and the earth wire.
Sliding glass doors
Are inflexible
The roller is not adjusted properly.
The tray is not horizontal.
Adjust the roller.
Adjust the try to be horizontal.
No water or water pressure is very low
Water pressure is not normal
Function switch valve is locked or not connected.
Water pipe cracked or blocked..
Check the water pressure.
Connect or repair and change the valve.
Check and clean the pipe.
 



 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Clean and maintenancefor massage bathtub:
1. For daily cleaning, the massage bathtub can be cleaned with common liquid detergents and soft cloth, but do not use detergents containing acetone or ammonia. If there are stains and sticky tapes sticking to the surface of the tub body, it is possible to remove them by wiping gently with soft cloth socked by a little amount of gasoline.
2. Scratches on the surface of the tub body can be removed by burnishing with 150# water-proof abrasive paper with water, applying some toothpaste on them and then polishing with soft cloth.
3. Scale on the surface of the tub body can be removed by wiping with soft cloth and detergents containing weak-acid substances such as lemonade and vinegar, which should be heated slightly beforehand.
4. If there are any foreign objects such as hairs blocking in the water recovery apparatus and the nozzle, tack them apart and clean them.
5. It is not necessary to frequently wipe the surface of the electroplated parts, nor should these parts come into contact with such chemicals as organic solvents. Be careful: gas from glass cement with acid substances are harmful to the surface of electroplated parts.
6. Do not wipe the surface of the tub body with rough-surface objects or detergents containing chemical solvents or particles.
7. Do not beat or scratch the surface of the tub body with hard objects or cutting tools. Burning cigarette ends or anying whose temperature is higher than 100? must be kept away from the surface of the tub.
8. Cleaning of hydraulic massage device: Fill up the tub with hot water (40?), add detergent in the proportion of 2g/liter, turn on the pump for hydraulic massage for about 5 minutes, turn off the pump and drain the water, then fill up the tub with cold water, turn on the pump for hydraulic massage for about 3 minutes, turn off the pump, drain the water and wipe the tub dry.
9. Test the protective function of the ground fault circuit interrupter every 2 months.
10. Check regularly whether the supply cords, switches and connectors are damaged by mice, worms or ants.
11. Check regularly whether intake pipes and drain pipes or hoses are broken or looped, and whether the drainage is in good condition.
12. In storage, do not put the bathtubs up-side down, nor one on end of another. It is strictly prohibited to store bathtubs together with organic solvents like formic acid and formaldehyde.
13. Handle with care when transporting the bathtub. Be sure to make them free from heavy burden, impacts and violent shocks.
14. If the bathtub is to be put idle for a long time, drain it thoroughly, keep it in a dry and well ventilated place free from corrosive gas.
Trouble
Cause
Remedy
No power or the protective interrupter trips
Loose contact in power supply
Check and fix the connection
Electric leakage or bad earth in power source or circuit
Check the power source, circuit and ground wire, get rid of electric leakage and bad earth
No shower or shower too weak
Abnormal hydraulic pressure
Check the hydraulic pressure in the water supply
Function shifting value not connected or failure
Connect it, or open and repair it
Leakage or block in water supply pipe
Replace, or check and clear up the pipe
Filter blocked in the high-pressure pipe of the hot and cold water valve
Clear up the filter and high-pressure pipe
Massage pump failure
Not enough water in the tub
Pour water until it goes above the water level detector
Failure in main power supply for the pump
Check and switch on the power
Pump motor burnt
Check and test the motor to see whether there is short-circuit or open-circuit. Replace the motor if it has been burnt
Failure in adjusting massage strength
Abnormal voltage
Check the voltage
Adjusting valve has not been turned on or broken
Check or replace it
Water recovery apparatus blocked
Clean it
Hi-fi failure
Bed connection in audio plug
Repair the plug
Failure in main control case
Replace it
No photo signal output
Check the connection of photo source (e.g.: check whether the photo output of VCD player is correct.)
Failure in ozone sterilization
Not enough water in the tub
Pour water until it goes above the water level detector
The system broken
Replace it
Block or leakage in ozone pipe
Check the ozone pipe
Failure in remote control
Strong electromagnetic inference nearby
Operate manually rather than using the remote control
Batteries in the remote control have run out
Replace them
 

Company Add: Jieju City, Xindai Town, Pinghu City, Zhejiang province.
Tel: 0573-85688339 Fax: 0573-85687298 E-mail:huwei@aonisijj.com aonisijj@vip.163.com
Copyright © 2007 All right reserved by: Pinghu City Aonisi Sanitary Co.,Ltd. Tech supported by: Hangzhou Chuangyi IT Co.,Ltd. (EC-World Net).